Forskjell mellom versjoner av «Helsing»
(→Management: skriv litt om ipmi) |
(→ipmitool: more ipmitool commands) |
||
Linje 68: | Linje 68: | ||
=== ipmitool === | === ipmitool === | ||
− | Serveren støtter IPMI, så hvis kjernemodulen ipmi er lastet (automatisk, | + | Serveren støtter IPMI, så hvis kjernemodulen ipmi er lastet (automatisk, eller manuelt via <code>kldload ipmi</code>) så kan man gjøre ting som |
<pre> | <pre> | ||
root@helsing:~ # ipmitool -I open fru print | root@helsing:~ # ipmitool -I open fru print | ||
Linje 108: | Linje 108: | ||
Cooling/Fan Fault : false | Cooling/Fan Fault : false | ||
Front Panel Control : none | Front Panel Control : none | ||
+ | </pre> | ||
+ | |||
+ | andre kommandoer | ||
+ | <pre> | ||
+ | root@helsing:~ # ipmitool mc info | ||
+ | Device ID : 17 | ||
+ | Device Revision : 1 | ||
+ | Firmware Revision : 2.33 | ||
+ | IPMI Version : 2.0 | ||
+ | Manufacturer ID : 11 | ||
+ | Manufacturer Name : Hewlett-Packard | ||
+ | Product ID : 8192 (0x2000) | ||
+ | Product Name : Unknown (0x2000) | ||
+ | Device Available : yes | ||
+ | Provides Device SDRs : yes | ||
+ | Additional Device Support : | ||
+ | Sensor Device | ||
+ | SDR Repository Device | ||
+ | SEL Device | ||
+ | FRU Inventory Device | ||
+ | |||
+ | root@helsing:~ # ipmitool mc getsysinfo system_name | ||
+ | ProLiant DL380 G5 | ||
+ | |||
+ | root@helsing:~ # ipmitool chassis restart_cause | ||
+ | System restart cause: unknown | ||
+ | |||
+ | root@helsing:~ # ipmitool sdr | ||
+ | UID Light | 0x00 | ok | ||
+ | Int. Health LED | 0x00 | ok | ||
+ | Ext. Health LED | 0x00 | ok | ||
+ | Power Supply 1 | 0x00 | ok | ||
+ | Power Supply 2 | disabled | ns | ||
+ | Power Supplies | 0x00 | ok | ||
+ | VRM 1 | 0x00 | ok | ||
+ | VRM 2 | disabled | ns | ||
+ | Fan 1 | 78.01 percent | ok | ||
+ | Fan 2 | 78.01 percent | ok | ||
+ | Fan 3 | 63.11 percent | ok | ||
+ | Fan 4 | 79.97 percent | ok | ||
+ | Fan 5 | 79.97 percent | ok | ||
+ | Fan 6 | 79.97 percent | ok | ||
+ | Fans | 0x00 | ok | ||
+ | Temp 1 | 50 degrees C | ok | ||
+ | Temp 2 | 35 degrees C | ok | ||
+ | Temp 3 | 39 degrees C | ok | ||
+ | Temp 4 | 39 degrees C | ok | ||
+ | Temp 5 | 49 degrees C | ok | ||
+ | Temp 6 | disabled | ns | ||
+ | Temp 7 | disabled | ns | ||
+ | Power Meter | 300 Watts | ok | ||
+ | |||
+ | root@helsing:~ # ipmitool sensor | ||
+ | UID Light | 0x0 | discrete | 0x0080| na | na | na | na | na | na | ||
+ | Int. Health LED | 0x0 | discrete | 0x0080| na | na | na | na | na | na | ||
+ | Ext. Health LED | 0x0 | discrete | 0x0080| na | na | na | na | na | na | ||
+ | Power Supply 1 | 0x0 | discrete | 0x0180| na | na | na | na | na | na | ||
+ | Power Supply 2 | na | discrete | na | na | na | na | na | na | na | ||
+ | Power Supplies | 0x0 | discrete | 0x0880| na | na | na | na | na | na | ||
+ | VRM 1 | 0x0 | discrete | 0x0280| na | na | na | na | na | na | ||
+ | VRM 2 | na | discrete | na | na | na | na | na | na | na | ||
+ | Fan 1 | 78.008 | percent | ok | na | na | na | na | na | na | ||
+ | Fan 2 | 78.008 | percent | ok | na | na | na | na | na | na | ||
+ | Fan 3 | 63.112 | percent | ok | na | na | na | na | na | na | ||
+ | Fan 4 | 79.968 | percent | ok | na | na | na | na | na | na | ||
+ | Fan 5 | 79.968 | percent | ok | na | na | na | na | na | na | ||
+ | Fan 6 | 79.968 | percent | ok | na | na | na | na | na | na | ||
+ | Fans | 0x0 | discrete | 0x0180| na | na | na | na | na | na | ||
+ | Temp 1 | 50.000 | degrees C | ok | 0.000 | 0.000 | 0.000 | 67.000 | 70.000 | 75.000 | ||
+ | Temp 2 | 35.000 | degrees C | ok | 0.000 | 0.000 | 0.000 | 37.000 | 39.000 | 44.000 | ||
+ | Temp 3 | 39.000 | degrees C | ok | 0.000 | 0.000 | 0.000 | 68.000 | 127.000 | 127.000 | ||
+ | Temp 4 | 39.000 | degrees C | ok | 0.000 | 0.000 | 0.000 | 68.000 | 127.000 | 127.000 | ||
+ | Temp 5 | 49.000 | degrees C | ok | 0.000 | 0.000 | 0.000 | 74.000 | 77.000 | 82.000 | ||
+ | Temp 6 | na | | na | 0.000 | 0.000 | 0.000 | 68.000 | 127.000 | 127.000 | ||
+ | Temp 7 | na | | na | 0.000 | 0.000 | 0.000 | 68.000 | 127.000 | 127.000 | ||
+ | Power Meter | 298 | Watts | ok | na | na | na | na | na | na | ||
+ | |||
+ | root@helsing:~ # ipmitool sel | ||
+ | SEL Information | ||
+ | Version : 1.5 (v1.5, v2 compliant) | ||
+ | Entries : 0 | ||
+ | Free Space : 1024 bytes | ||
+ | Percent Used : 0% | ||
+ | Last Add Time : Not Available | ||
+ | Last Del Time : 10/16/2008 14:38:35 | ||
+ | Overflow : false | ||
+ | Supported Cmds : 'Reserve' | ||
+ | |||
+ | root@helsing:~ # ipmitool user summary 2 | ||
+ | Maximum IDs : 12 | ||
+ | Enabled User Count : 3 | ||
+ | Fixed Name Count : 0 | ||
+ | root@helsing:~ # ipmitool user list 2 | ||
+ | ID Name Callin Link Auth IPMI Msg Channel Priv Limit | ||
+ | 1 Administrator true false true ADMINISTRATOR | ||
+ | 2 itsos true false true ADMINISTRATOR | ||
+ | 3 tingo true false true ADMINISTRATOR | ||
+ | 4 (Empty User) true false false NO ACCESS | ||
+ | 5 (Empty User) true false false NO ACCESS | ||
+ | 6 (Empty User) true false false NO ACCESS | ||
+ | 7 (Empty User) true false false NO ACCESS | ||
+ | 8 (Empty User) true false false NO ACCESS | ||
+ | 9 (Empty User) true false false NO ACCESS | ||
+ | 10 (Empty User) true false false NO ACCESS | ||
+ | 11 (Empty User) true false false NO ACCESS | ||
+ | 12 (Empty User) true false false NO ACCESS | ||
+ | |||
+ | root@helsing:~ # ipmitool channel info 2 | ||
+ | Channel 0x2 info: | ||
+ | Channel Medium Type : 802.3 LAN | ||
+ | Channel Protocol Type : IPMB-1.0 | ||
+ | Session Support : multi-session | ||
+ | Active Session Count : 0 | ||
+ | Protocol Vendor ID : 7154 | ||
+ | Volatile(active) Settings | ||
+ | Alerting : disabled | ||
+ | Per-message Auth : disabled | ||
+ | User Level Auth : enabled | ||
+ | Access Mode : always available | ||
+ | Non-Volatile Settings | ||
+ | Alerting : disabled | ||
+ | Per-message Auth : disabled | ||
+ | User Level Auth : enabled | ||
+ | Access Mode : always available | ||
+ | |||
+ | oot@helsing:~ # ipmitool dcmi discover | ||
+ | Supported DCMI capabilities: | ||
+ | |||
+ | Mandatory platform capabilties | ||
+ | Identification support available | ||
+ | SEL logging available | ||
+ | Chassis power available | ||
+ | Temperature monitor available | ||
+ | |||
+ | Optional platform capabilties | ||
+ | Power management available | ||
+ | |||
+ | Managebility access capabilties | ||
+ | In-band KCS channel available | ||
+ | Out-of-band primary LAN channel available | ||
+ | SOL enabled | ||
+ | VLAN capable | ||
+ | |||
+ | Mandatory platform attributes: | ||
+ | |||
+ | SEL Attributes: | ||
+ | SEL automatic rollover is enabled | ||
+ | 512 SEL entries | ||
+ | |||
+ | Identification Attributes: | ||
+ | GUID | ||
+ | Asset tag | ||
+ | |||
+ | Temperature Monitoring Attributes: | ||
+ | inlet | ||
+ | cpu | ||
+ | baseboard | ||
+ | |||
+ | Optional Platform Attributes: | ||
+ | |||
+ | Power Management: | ||
+ | Slave address of device: 20h (8bits)(Satellite/External controller) | ||
+ | Channel number is 0h (Primary BMC) | ||
+ | Device revision is 1 | ||
+ | |||
+ | Manageability Access Attributes: | ||
+ | Primary LAN channel number: 2 is available | ||
+ | Secondary LAN channel is not available for OOB | ||
+ | No serial channel is available | ||
+ | |||
</pre> | </pre> | ||
Revisjonen fra 9. aug. 2022 kl. 17:38
Helsing er en HP ProLiant DL380 G5[1] server donert til Bitraf.
Innhold
Operativsystem
FreeBSD er installert på denne serveren.
Spesifikasjoner
- prosessor
- 1 x Xeon 4-core (mulighet for 2 prosessorer)
- minne
- 20 GB (2 x 4GB + 3 x 2 x 2 GB) 8 slots av 8 i bruk (was: 1 GB (2 x 512MB), 2 slots av 8 i bruk (maximum minne er 32 GB - 8 x 4 GB), PC2-5300 (DDR2-667))
- chipset
- Intel 5000P
- nettverk
- dual NC373i Multifunction Gigabit adapters
- storage controller
- Smart Array E200[2]
- usb ports
- 5 x usb 2.0 (2 front, 2 back, 1 inside)
- hard drive slots
- 8 SATA SFF
- hard drives
- 2 x 300 GB, 6 x 146 GB
- remote management
- iLO 2[3]
- power supply
- 800 W (optional redundant power supply)
Firmware
BIOS
Nåværende versjon av BIOS er
</>hpiLO-> show /system1/firmware1 status=0 status_tag=COMMAND COMPLETED /system1/firmware1 Targets Properties version=P56 date=05/02/2011 Verbs cd version exit show set
iLO 2
iLO 2 (integrated Lights Out management) er HP (tidligere Compaq) sitt remote management verktøy for ProLiant servere.
- 2020-06-03
- oppgradert iLO 2 firmware til versjon 2.33. Tingo (diskusjon) 5. jun. 2020 kl. 16:55 (CEST)
Management
iLO 2 via nettleser funker, men remote console og virtual media krever java applets, dvs. at ingen moderne nettlesere støtter det. Alternativ: Javafox[4] som er et docker-image med gammel nettleser og Java-plugins.
iLO 2 via ssh funker, der funker også vm (virtual media), men images må legges på en server. Eksempel
</>hpiLO-> vm cdrom get VM Applet = Disconnected Boot Option = BOOT_ONCE Write Protect = Yes Image Inserted = Connected Image URL = http://heim.bitraf.no/tingo/files/iso/FreeBSD-12.1-RELEASE-amd64-disc1.iso </>hpiLO-> vm cdrom insert http://heim.bitraf.no/tingo/files/iso/FreeBSD-11.3-RELEASE-amd64-disc1.iso </>hpiLO-> vm cdrom set boot_once </>hpiLO-> vm cdrom get VM Applet = Disconnected Boot Option = BOOT_ONCE Write Protect = Yes Image Inserted = Connected Image URL = http://heim.bitraf.no/tingo/files/iso/FreeBSD-11.3-RELEASE-amd64-disc1.iso
Utfordringen med iLO 2 via ssh er remote console. Det er støttet for text only konsoll (via kommandoen textcons
), men så fort operativsystemet bytter til grafisk skjerm på konsollet, så mister du bildet.
ipmitool
Serveren støtter IPMI, så hvis kjernemodulen ipmi er lastet (automatisk, eller manuelt via kldload ipmi
) så kan man gjøre ting som
root@helsing:~ # ipmitool -I open fru print FRU Device Description : Builtin FRU Device (ID 0) Chassis Type : Rack Mount Chassis Chassis Part Number : 458568-421 Chassis Serial : CZC84158PX Board Mfg Date : Mon Jan 1 01:00:00 1996 Board Mfg : HP Board Product : ProLiant DL380 G5 Board Serial : CZC84158PX Board Part Number : 458568-421 Product Manufacturer : HP Product Name : ProLiant DL380 G5 Product Part Number : 458568-421 Product Serial : CZC84158PX Product Asset Tag : root@helsing:~ # ipmitool -I open sdr type temperature Temp 1 | 10h | ok | 16.5 | 50 degrees C Temp 2 | 11h | ok | 39.9 | 35 degrees C Temp 3 | 12h | ok | 3.10 | 38 degrees C Temp 4 | 13h | ok | 3.11 | 38 degrees C Temp 5 | 14h | ok | 19.1 | 49 degrees C Temp 6 | 15h | ns | 3.12 | Disabled Temp 7 | 16h | ns | 3.13 | Disabled root@helsing:~ # ipmitool -I open chassis status System Power : on Power Overload : false Power Interlock : inactive Main Power Fault : false Power Control Fault : false Power Restore Policy : previous Last Power Event : Chassis Intrusion : inactive Front-Panel Lockout : inactive Drive Fault : false Cooling/Fan Fault : false Front Panel Control : none
andre kommandoer
root@helsing:~ # ipmitool mc info Device ID : 17 Device Revision : 1 Firmware Revision : 2.33 IPMI Version : 2.0 Manufacturer ID : 11 Manufacturer Name : Hewlett-Packard Product ID : 8192 (0x2000) Product Name : Unknown (0x2000) Device Available : yes Provides Device SDRs : yes Additional Device Support : Sensor Device SDR Repository Device SEL Device FRU Inventory Device root@helsing:~ # ipmitool mc getsysinfo system_name ProLiant DL380 G5 root@helsing:~ # ipmitool chassis restart_cause System restart cause: unknown root@helsing:~ # ipmitool sdr UID Light | 0x00 | ok Int. Health LED | 0x00 | ok Ext. Health LED | 0x00 | ok Power Supply 1 | 0x00 | ok Power Supply 2 | disabled | ns Power Supplies | 0x00 | ok VRM 1 | 0x00 | ok VRM 2 | disabled | ns Fan 1 | 78.01 percent | ok Fan 2 | 78.01 percent | ok Fan 3 | 63.11 percent | ok Fan 4 | 79.97 percent | ok Fan 5 | 79.97 percent | ok Fan 6 | 79.97 percent | ok Fans | 0x00 | ok Temp 1 | 50 degrees C | ok Temp 2 | 35 degrees C | ok Temp 3 | 39 degrees C | ok Temp 4 | 39 degrees C | ok Temp 5 | 49 degrees C | ok Temp 6 | disabled | ns Temp 7 | disabled | ns Power Meter | 300 Watts | ok root@helsing:~ # ipmitool sensor UID Light | 0x0 | discrete | 0x0080| na | na | na | na | na | na Int. Health LED | 0x0 | discrete | 0x0080| na | na | na | na | na | na Ext. Health LED | 0x0 | discrete | 0x0080| na | na | na | na | na | na Power Supply 1 | 0x0 | discrete | 0x0180| na | na | na | na | na | na Power Supply 2 | na | discrete | na | na | na | na | na | na | na Power Supplies | 0x0 | discrete | 0x0880| na | na | na | na | na | na VRM 1 | 0x0 | discrete | 0x0280| na | na | na | na | na | na VRM 2 | na | discrete | na | na | na | na | na | na | na Fan 1 | 78.008 | percent | ok | na | na | na | na | na | na Fan 2 | 78.008 | percent | ok | na | na | na | na | na | na Fan 3 | 63.112 | percent | ok | na | na | na | na | na | na Fan 4 | 79.968 | percent | ok | na | na | na | na | na | na Fan 5 | 79.968 | percent | ok | na | na | na | na | na | na Fan 6 | 79.968 | percent | ok | na | na | na | na | na | na Fans | 0x0 | discrete | 0x0180| na | na | na | na | na | na Temp 1 | 50.000 | degrees C | ok | 0.000 | 0.000 | 0.000 | 67.000 | 70.000 | 75.000 Temp 2 | 35.000 | degrees C | ok | 0.000 | 0.000 | 0.000 | 37.000 | 39.000 | 44.000 Temp 3 | 39.000 | degrees C | ok | 0.000 | 0.000 | 0.000 | 68.000 | 127.000 | 127.000 Temp 4 | 39.000 | degrees C | ok | 0.000 | 0.000 | 0.000 | 68.000 | 127.000 | 127.000 Temp 5 | 49.000 | degrees C | ok | 0.000 | 0.000 | 0.000 | 74.000 | 77.000 | 82.000 Temp 6 | na | | na | 0.000 | 0.000 | 0.000 | 68.000 | 127.000 | 127.000 Temp 7 | na | | na | 0.000 | 0.000 | 0.000 | 68.000 | 127.000 | 127.000 Power Meter | 298 | Watts | ok | na | na | na | na | na | na root@helsing:~ # ipmitool sel SEL Information Version : 1.5 (v1.5, v2 compliant) Entries : 0 Free Space : 1024 bytes Percent Used : 0% Last Add Time : Not Available Last Del Time : 10/16/2008 14:38:35 Overflow : false Supported Cmds : 'Reserve' root@helsing:~ # ipmitool user summary 2 Maximum IDs : 12 Enabled User Count : 3 Fixed Name Count : 0 root@helsing:~ # ipmitool user list 2 ID Name Callin Link Auth IPMI Msg Channel Priv Limit 1 Administrator true false true ADMINISTRATOR 2 itsos true false true ADMINISTRATOR 3 tingo true false true ADMINISTRATOR 4 (Empty User) true false false NO ACCESS 5 (Empty User) true false false NO ACCESS 6 (Empty User) true false false NO ACCESS 7 (Empty User) true false false NO ACCESS 8 (Empty User) true false false NO ACCESS 9 (Empty User) true false false NO ACCESS 10 (Empty User) true false false NO ACCESS 11 (Empty User) true false false NO ACCESS 12 (Empty User) true false false NO ACCESS root@helsing:~ # ipmitool channel info 2 Channel 0x2 info: Channel Medium Type : 802.3 LAN Channel Protocol Type : IPMB-1.0 Session Support : multi-session Active Session Count : 0 Protocol Vendor ID : 7154 Volatile(active) Settings Alerting : disabled Per-message Auth : disabled User Level Auth : enabled Access Mode : always available Non-Volatile Settings Alerting : disabled Per-message Auth : disabled User Level Auth : enabled Access Mode : always available oot@helsing:~ # ipmitool dcmi discover Supported DCMI capabilities: Mandatory platform capabilties Identification support available SEL logging available Chassis power available Temperature monitor available Optional platform capabilties Power management available Managebility access capabilties In-band KCS channel available Out-of-band primary LAN channel available SOL enabled VLAN capable Mandatory platform attributes: SEL Attributes: SEL automatic rollover is enabled 512 SEL entries Identification Attributes: GUID Asset tag Temperature Monitoring Attributes: inlet cpu baseboard Optional Platform Attributes: Power Management: Slave address of device: 20h (8bits)(Satellite/External controller) Channel number is 0h (Primary BMC) Device revision is 1 Manageability Access Attributes: Primary LAN channel number: 2 is available Secondary LAN channel is not available for OOB No serial channel is available
Historikk
Arbeid som er gjort.
- 2022-08-09
- upgraded FreeBSD via
freebsd-update -r 13.1-RELEASE upgrade
, followed by
root@helsing:~ # freebsd-update install src component not installed, skipped Installing updates... Kernel updates have been installed. Please reboot and run "/usr/sbin/freebsd-update install" again to finish installing updates.
reboot, then
root@helsing:~ # freebsd-update install src component not installed, skipped Installing updates...Scanning //usr/share/certs/blacklisted for certificates... Scanning //usr/share/certs/trusted for certificates... Scanning //usr/local/share/certs for certificates... done.
and now the server runs
root@helsing:~ # freebsd-version -ku 13.1-RELEASE 13.1-RELEASE
Tingo (diskusjon) 9. aug. 2022 kl. 17:53 (CEST)
- 2022-08-09
- packages upgraded via
sudo pkg upgrade
. From /var/log/messages
Aug 9 16:52:25 helsing pkg[20615]: libunwind upgraded: 20211201 -> 20211201_1 Aug 9 16:52:26 helsing pkg[20615]: ruby27-gems-3.3.10 deinstalled Aug 9 16:52:56 helsing pkg[20615]: ruby upgraded: 2.7.5_1,1 -> 3.0.4_2,1 Aug 9 16:52:56 helsing pkg[20615]: ca_root_nss upgraded: 3.76 -> 3.78 Aug 9 16:52:57 helsing pkg[20615]: ruby30-gems-3.3.17 installed Aug 9 16:52:57 helsing pkg[20615]: rubygem-trollop reinstalled: 2.9.10 -> 2.9.10 Aug 9 16:52:57 helsing pkg[20615]: rubygem-mtrc reinstalled: 0.0.4 -> 0.0.4 Aug 9 16:52:57 helsing pkg[20615]: rubygem-beefcake reinstalled: 1.2.0 -> 1.2.0 Aug 9 16:52:57 helsing pkg[20615]: rubygem-riemann-client reinstalled: 0.2.6_1 -> 0.2.6_1 Aug 9 16:52:57 helsing pkg[20615]: rubygem-json upgraded: 2.5.1 -> 2.6.2 Aug 9 16:52:58 helsing pkg[20615]: rubygem-optimist reinstalled: 3.0.1 -> 3.0.1 Aug 9 16:53:18 helsing pkg[20615]: python38 upgraded: 3.8.13 -> 3.8.13_2 Aug 9 16:53:18 helsing pkg[20615]: rubygem-riemann-tools reinstalled: 0.2.14 -> 0.2.14 Aug 9 16:53:19 helsing pkg[20615]: sudo upgraded: 1.9.10 -> 1.9.11p3 Aug 9 16:53:19 helsing pkg[20615]: python3 reinstalled: 3_3 -> 3_3
Tingo (diskusjon) 9. aug. 2022 kl. 16:56 (CEST)
- 2022-08-09
- configure /etc/nsswitch.conf for mdns - before
root@helsing:~ # grep ^hosts /etc/nsswitch.conf hosts: files dns
after
root@helsing:~ # grep ^hosts /etc/nsswitch.conf hosts: files mdns_minimal [NOTFOUND=return] dns mdns
and configure avahi-daemon to start up (also requires dbus) by
root@helsing:~ # sysrc dbus_enable=yes dbus_enable: -> yes root@helsing:~ # sysrc avahi_daemon_enable=yes avahi_daemon_enable: -> yes
Tingo (diskusjon) 9. aug. 2022 kl. 16:12 (CEST)
Finally, start dbus and avahi-damon
root@helsing:~ # service dbus start Starting dbus. root@helsing:~ # service avahi-daemon start Starting avahi-daemon.
Tingo (diskusjon) 9. aug. 2022 kl. 16:14 (CEST)
- 2022-08-09
- install mdns_nss and avahi via
pkg install nss_mdns
, /var/log/messages shows
Aug 9 15:48:06 helsing su[10822]: tingo to root on /dev/pts/1 Aug 9 15:50:05 helsing pkg[11100]: pkg upgraded: 1.17.5_1 -> 1.18.3 Aug 9 15:50:38 helsing pkg[11157]: xorgproto-2022.1 installed Aug 9 15:50:38 helsing pkg[11157]: libXau-1.0.9 installed Aug 9 15:50:38 helsing pkg[11157]: libpthread-stubs-0.4 installed Aug 9 15:50:38 helsing pkg[11157]: libXdmcp-1.1.3 installed Aug 9 15:50:39 helsing pkg[11157]: libxcb-1.15 installed Aug 9 15:50:40 helsing pkg[11157]: libICE-1.0.10,1 installed Aug 9 15:50:40 helsing pkg[11157]: libffi upgraded: 3.3_1 -> 3.4.2 Aug 9 15:50:41 helsing pkg[11157]: libxml2-2.9.13_2 installed Aug 9 15:50:52 helsing pkg[11157]: python39-3.9.13 installed Aug 9 15:50:53 helsing pkg[11157]: pcre-8.45_1 installed Aug 9 15:50:53 helsing pkg[11157]: libSM-1.2.3,1 installed Aug 9 15:50:54 helsing pkg[11157]: libX11-1.7.2,1 installed Aug 9 15:50:55 helsing pkg[11157]: libiconv-1.16 installed Aug 9 15:50:55 helsing pkg[11157]: expat-2.4.8 installed Aug 9 15:50:56 helsing pkg[11157]: dbus-1.14.0,1 installed Aug 9 15:50:59 helsing pkg[11157]: glib-2.72.2,2 installed Aug 9 15:50:59 helsing pkg[11157]: dbus-glib-0.112 installed Aug 9 15:50:59 helsing pkg[11157]: gnome_subr-1.0 installed Aug 9 15:50:59 helsing pkg[11157]: libdaemon-0.14_1 installed Aug 9 15:51:00 helsing pkg[11157]: libevent-2.1.12 installed Aug 9 15:51:00 helsing pkg[11157]: gdbm-1.23 installed Aug 9 15:51:01 helsing pkg[11157]: avahi-app-0.8 installed Aug 9 15:51:01 helsing pkg[11157]: libffi33-3.3_2 installed Aug 9 15:51:01 helsing pkg[11157]: nss_mdns-0.14.1.20200624 installed
Tingo (diskusjon) 9. aug. 2022 kl. 15:56 (CEST)
- 2022-04-15
- packages upgraded via
sudo pkg upgrade
. From /var/log/messages
Apr 15 20:08:29 helsing pkg[2348]: pkg upgraded: 1.16.3 -> 1.17.5_1 Apr 15 20:09:17 helsing pkg[2431]: libunwind upgraded: 20201110 -> 20211201 Apr 15 20:09:17 helsing pkg[2431]: libedit upgraded: 3.1.20210216,1 -> 3.1.20210910,1 Apr 15 20:09:49 helsing pkg[2431]: ruby upgraded: 2.7.3_2,1 -> 2.7.5_1,1 Apr 15 20:09:49 helsing pkg[2431]: ca_root_nss-3.76 installed Apr 15 20:09:54 helsing pkg[2431]: ruby27-gems upgraded: 3.0.8 -> 3.3.10 Apr 15 20:09:55 helsing pkg[2431]: readline upgraded: 8.1.1 -> 8.1.2 Apr 15 20:09:56 helsing pkg[2431]: sudo upgraded: 1.9.8 -> 1.9.10 Apr 15 20:09:56 helsing pkg[2431]: rubygem-json upgraded: 2.3.1 -> 2.5.1 Apr 15 20:10:15 helsing pkg[2431]: python38 upgraded: 3.8.10 -> 3.8.13
Tingo (diskusjon) 15. apr. 2022 kl. 20:14 (CEST)
- FreeBSD upgraded via
sudo freebsd-update fetch; sudo freebsd-update install
. after a reboot, FreeBSD 11.0-release-p11 is in
tingo@helsing:~ $ freebsd-version -ku 13.0-RELEASE-p11 13.0-RELEASE-p11
kernel
tingo@helsing:~ $ uname -a FreeBSD helsing.lan.bitraf.no 13.0-RELEASE-p11 FreeBSD 13.0-RELEASE-p11 #0: Tue Apr 5 18:54:35 UTC 2022 root@amd64-builder.daemonology.net:/usr/obj/usr/src/amd64.amd64/sys/GENERIC amd64
Tingo (diskusjon) 15. apr. 2022 kl. 20:05 (CEST)
- 2021-10-18
- FreeBSD 13.0-release er installert på serveren.
tingo@helsing:~ $ freebsd-version ; uname -a 13.0-RELEASE FreeBSD helsing.lan.bitraf.no 13.0-RELEASE FreeBSD 13.0-RELEASE #0 releng/13.0-n244733-ea31abc261f: Fri Apr 9 04:24:09 UTC 2021 root@releng1.nyi.freebsd.org:/usr/obj/usr/src/amd64.amd64/sys/GENERIC amd64
Tingo (diskusjon) 15. apr. 2022 kl. 19:44 (CEST)
- 2021-09-16
- tested Javafox for remote console and virtual media applet. With a small fix to the Dockerfile, both remote console and virtual media applets start. I've tested the remote console, it works. Tingo (diskusjon) 17. sep. 2021 kl. 15:18 (CEST)
- 2020-06-18
- need packages
firmware-bnx2
for the network interfaces. Could probably use some HP related packacges too, like hpacucli, hpssacli. And probably something for temperature monitoring / fan control. - 2020-06-18
- minne - Helsing har fått 20 GB minne, fordelt på 2 x 4GB, 3 x (2 x 2 GB). Alle 8 slots brukt.
- 2020-06-18
- minne i server, som rapport via iLo, ssh
</>hpiLO-> show /system1/memory1 status=0 status_tag=COMMAND COMPLETED /system1/memory1 Targets Properties size=512MB speed=667MHz location=DIMM 1A Verbs cd version exit show set </>hpiLO-> show /system1/memory2 status=0 status_tag=COMMAND COMPLETED /system1/memory2 Targets Properties size=not installed speed=not installed location=DIMM 2C Verbs cd version exit show set
- 2020-06-10
- koblet nettverkskabel til nettverksport 1 på serveren. Tingo (diskusjon) 10. jun. 2020 kl. 16:01 (CEST)